作 者:夏佰林[1] 赵东亮[1] 代彦军[1] 李勇[1]
机构地区:[1]上海交通大学机械与动力工程学院,上海200240
出 处:《太阳能学报》2012年第9期1560-1564,共5页Acta Energiae Solaris Sinica
基 金:"十一五"国家科技支撑计划(2008BAJ12B01)
摘 要:对一种蛇形流道太阳能平板空气集热器的集热性能进行研究,揭示流道转弯数N与蛇形流道集热器集热性能之间的关系,得到集热器流道转弯数的推荐值。指出大转弯数蛇形流道空气集热器FR值可近似用N=1时的FR值进行替代研究,当N>5时,集热器热迁移因子FR与N=1误差不超过5%。通过理论研究,获得带金属隔板蛇形流道集热器热迁移因子FR的理论表达式,并对集热器进行优化,使集热器热迁移因子FR提高到0.81。A flat plate solar air collector with serpentine flow passages was studied. The relationships between the efficiency factor, the heat-removal factor of the solar air collector and the turning numbers, and found the recom- mended values. The article also pointed out that the heat removal factor FR of large turning number air collector can be instead by N = 1 approximately. When N 〉 5, the error of collector heat removal factor FR are less than 5%, compared with N = 1. The theoretical formula of the collector's thermal efficiency is obtained, which can be used for design and application of such kind of collectors.
分 类 号:TK512[动力工程及工程热物理—热能工程]