R417A热泵空调换热器的温度分布特性  被引量:2

Temperature Distribution of R417A Heat Pump Type Air Conditioner Heat Exchangers

在线阅读下载全文

作  者:刘艳[1] 刘颖[1] 王芳[1] 吴建成[1] 薛梅[1] 

机构地区:[1]上海理工大学,上海200093

出  处:《流体机械》2012年第8期56-60,共5页Fluid Machinery

基  金:上海市重点学科建设资助项目(S30503)

摘  要:对一台以R417A为工质的热泵型房间空调换热器在不同室外干、湿球温度工况下的温度分布情况进行了试验研究和分析。通过对管翅式换热器温度分布规律的研究,找出其换热特性,在对试验结果进行综合分析的基础上,提出了优化设计建议。It was investigated the condition of temperature distribution of heat pump room air conditioning heat exchanger in dif- ferent outdoor dry,web- bulb temperature , R417A is used as working substance , under the condition, the experiment research and analysis was carried on. Based on the study of temperature distribution regularity of tube - and - fin type heat exchanger, and find out the heat transfer characteristics, based on the analysis of the experimental results, the optirhization design is put forward as a suggestion

关 键 词:R417A 热泵空调器 干湿球温度 管翅式换热器 换热特性 

分 类 号:TB65[一般工业技术—制冷工程]

 