摘  要:基于对广西输电铁塔大气环境腐蚀性评估及在用输电铁塔腐蚀防护调查,分析了广西输电铁塔腐蚀防护存在的问题,提出防治对策,建议对铁塔腐蚀进行差异性防护,建立入网铁塔构件镀锌层质量缺陷抽检制度,并尽快制定输电铁塔防腐蚀技术规范。Based on the corrosion assessment of atmospheric environment and the corrosion protection investigation of transmission tower in Guangxi,corrosion protection problems of transmission tower in Guangxi are analyzed. Countermeasures are proposed. It is suggested that differentiation protection should be used in steel tower corrosion, the quality defect sampling system of zinc coating of steel tower component should be established, and the technology specification of anti-corrosion for transmission tower should he developed.

关 键 词:输电铁塔 热度锌 腐蚀 