检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:华国辉[1]
机构地区:[1]三峡大学三峡库区地质灾害教育部重点实验室,湖北宜昌443002
出 处:《人民黄河》2012年第9期124-126,共3页Yellow River
摘 要:高边坡预应力锚索防护工程设计的可靠性直接影响到高边坡的安全和稳定。以湖北省巴乐县某高切坡防护工程为例,使用与实例的实际情况相同的钢绞线制成锚索,安装后进行基本试验,最大试验荷载为钢绞线抗拉强度标准值的80%,检测预应力锚索设计的合理性。试验结果表明,在各级荷载作用下各试验锚索的锚头总弹性位移均满足要求,当施加拉力达到最大试验荷载1 034 kN时,预应力锚索均没有发生破坏,从而验证了该实例600 kN级预应力锚索设计的正确性。The reliability of protection design of the high slope prestressed anchor directly affects the security and stability of high slope. A case study of one high slop potection works in Badong City of Hubei Province was shown in the thesis. The anchor made in steel strand which was same to practical situation of the case, and the basic test after installation to detect the rationality of prestressed anchor design was conducted. The maxi- mum test load was 80% of standard value of tensile strength of steel strand. The test results show that the total elastic displacement of all anchor head meets the requirement under different load levels, and when the pulling reaches the maximum test load I 034 kN, the prestressed anchor is not damaged, thus the correctness of 600 kN prestressed anchor design in the case has been verified.
关 键 词:预应力锚索 基本试验 伸长量 弹性位移 承载能力 案例研究
分 类 号:TV332[水利工程—水工结构工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.117