电测量变送器检定装置测量结果不确定度评定  被引量:3

The Uncertainty Evaluation of Measurement Results with the Calibrating Device of Electrical Measuring Transducer

在线阅读下载全文

作  者:吴瀛 祁舒喆 

机构地区:[1]南方电网超高压公司检修试验中心,广州510663 [2]广东电网电力科学研究院,广州510080

出  处:《南方电网技术》2012年第4期84-86,共3页Southern Power System Technology

摘  要:按照JJF 1033—2008《计量标准考核规范》及JJG01—1994《电测量变送器检定规程》的要求,阐述了电测量变送器检定装置的不确定度评定方法和步骤以及检定结果验证,以利于电力系统计量检定机构正确全面地评定此类测量不确定度和为电测量变送器检定装置建立适当的计量标准。According to the "JJF 1033-2008, Rule for the Examination of Measurement Strandard" and "JJG01-1994, Verification Regulation of Electrical Measuring Transducer", this paper introduces the methods and procedures of uncertainty evaluation and the test results validation for the electrical measuring transducer in order to do a favor for the power-system metrology institute to correctly and comprehensively evaluate the uncertainty of the measurement and to build up appropriate measurement standards for the electrical measuring transducer.

关 键 词:电测量变送器 测量不确定度评定 检定结果验证 

分 类 号:TM933[电气工程—电力电子与电力传动]

 