检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]青海出入境检验检疫局,西宁810000 [2]青海大学化工学院,西宁810000
出 处:《现代仪器》2012年第5期68-71,共4页Modern Instruments
基 金:国家质检总局科技计划项目(编号2011IK219)
摘 要:本研究采用直接固体进样-石墨炉原子吸收法(SS-GF AAS)测定沙棘维生素P粉中重金属铅的含量。通过对石墨炉工作程序的优化,同时采用基体改进剂技术,最终得到稳定而准确的结果,其结果与液体进样使用ICP-MS测量结果一致。本方法中RSD 2.29%-11.70%,回收率91.75%-114.05%,检出限0.0075ng。与湿法消解方法相比较,该方法无需样品前处理,具有简便、快速特点,同时可避免样品的稀释以及试剂的交叉污染带来的分析误差。Direct solid sampling graphite furnace atomic absorption spectrometry(SS-GF AAS) was used to determine Pb in sea buckthorn Vitamin P powder.After the program optimization and with an extremely careful selection of chemical modifier,the stable and accurate results could be obtained.The same results could finally be carried out by ICP-MS using liquid sampling.The RSD was between 1.23%~11.75%,the recovery rate was between 90.50%~106.13%%,the detection limit was 0.0035ng.Compared with liquid sampling graphite furnace AAS analysis,the Direct SS-GF AAS proved to be a good alternative to conventional methods of trace analysis after wet-chemical digestion and compared favorably with these methods,it can save a lot of work for sample processing,has benefits to avoid dilution and external contamination.