检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:崔广和[1] 杨智[1] 孙芳[1] 尤春玲[2] 张文晓[1]
机构地区:[1]滨州医学院附属医院超声医学科,山东滨州256603 [2]滨州医学院图书馆情报部,山东滨州256603
出 处:《中国医疗设备》2012年第10期141-142,共2页China Medical Devices
摘 要:目的应用动物模型分析影响声脉冲辐射力成像技术探测成功率的因素。方法应用7组动物模型,每组测量50次,观察每组成功次数,分析脂肪厚度、肋骨、角度及压力对探测成功率的影响。结果脂肪厚度、与肋骨垂直或平行、探测入射角度与探测成功率的影响没有统计学意义(P>0.05),探头加压对探测成功率的影响有显著统计学意义(P<0.01)。结论探头加压对声脉冲辐射力成像技术探测成功率的影响有显著统计学意义。Objective To analyze the influence factors of the acoustic radiation force impulse in animal models. Methods 50 times were measured in each animal model group of all 7 groups, observing the numbers of success of each group, analyzing the effects of fat thickness, ribs, angle and probe pressure on detection success rate. Results Fat thickness, vertical or parallel to ribs and detection angle for injection showed no statistical significance on the detection success rate (p〉O.05), while the influence of probe pressure showed statistical significance(p〈0.01). Conclusion The influence of probe pressure showed statistical significance on the success rate of acoustic radiation force impulse.
分 类 号:R445.1[医药卫生—影像医学与核医学]