检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:董少龙[1] 董开虎[1] 张金平[1] 李旭[1] 郭庆林[1]
机构地区:[1]河北大学物理科学与技术学院,河北保定071002
出 处:《河北大学学报(自然科学版)》2012年第5期472-476,共5页Journal of Hebei University(Natural Science Edition)
基 金:河北省自然科学基金资助项目(A2012201013)
摘 要:采用调Q Nd:YAG激光器激发诱导Cu合金的等离子体,系统研究了等离子体光谱强度随时间演化特性,并探究了不同环境气氛对激光诱导等离子体光谱强度的影响.实验结果表明:信噪比最佳的延时选择与分析光谱线激发电位密切相关,而受环境气氛、分析元素的熔点、沸点影响不大;氩气和氦-氩混合气体环境与空气环境相比,激光诱导等离子体光谱强度明显增强.Laser induced plasma of cuprum alloy was excited by Nd:YAG laser.Temporal characteristic of spectroscopy and influence that different ambient atmospheres worked to the intensity of spectroscopy were systemic investigated.The experimental result suggests that the choice of time to acquire the best spectrum is hardly related to ambient atmosphere,the melting point and boiling point of elements,it rests with the excitation potential of the spectral line;Compared with air,argon and mixture consisted of helium and argon makes the intensity of laser induced plasma spectroscopy increased significantly.
正在载入数据...