检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘锋[1] 姜友蕾[1] 熊芳芳[1] 马三剑[1]
机构地区:[1]苏州科技学院环保应用技术研究所,江苏苏州215011
出 处:《工业用水与废水》2012年第5期28-31,共4页Industrial Water & Wastewater
摘 要:采用UASB厌氧反应器在中温条件下处理头孢类抗生素制药废水。结果表明:当反应器稳定运行后,进水CODCr的质量浓度为14 300 mg/L,容积负荷可达到14.3 kg/(m3.d),CODCr的去除率能够稳定在85%左右,出水CODCr的质量浓度在2 500 mg/L以下,出水VFA的质量浓度在3 mmol/L左右,产气量达到17 L/d左右。试验取得了良好的处理效果,为利用厌氧技术处理头孢类抗生素废水提供了设计依据。UASB reactor was used to treat cephalosporin antibiotic pharmaceutical wastewater under moderate temperature. The results showed that, during the stable operation period of the reactor, when the mass concentration of the CODcr in the influent water was 14 300 mg/L, the volume loading could reach 14.3 kg/(m3. d), the removal rate of CODcr was kept at about 85%, the mass concentration of CODcr in the effluent water was below 2 500 mg/L, the mass concentration of VFA in the effluent water was about 3 mmol/L, the gas production amount reached about 17 L/d. The test achieved a good effect, which provided design basis for anaerobic technology treating cephalosporin antibiotic pharmaceutical wastewater.
关 键 词:上流式厌氧污泥床(UASB) 头孢类抗生素 制药废水
分 类 号:X787[环境科学与工程—环境工程] X703.1
正在载入数据...