某电厂烟气脱硝催化剂使用前后性能测试及失活分析  被引量:5

Performance testing and deactivation analysis of the catalyst for denitrification of flue gas from one power plant

在线阅读下载全文

作  者:林德海[1] 王中原[1] 宋宝华[1] 

机构地区:[1]中节能六合天融环保科技有限公司,北京100085

出  处:《工业催化》2012年第10期72-75,共4页Industrial Catalysis

摘  要:以某电厂SCR脱硝装置运行22 080 h的催化剂为研究对象,对催化剂进行脱硝率测试及化学表征。研究表明,运行了22 080 h的催化剂的脱硝率为57%,催化剂破碎和断裂较严重,比表面积下降2.48%~5.12%,XRD及XRF表征发现,催化剂被灰尘堵塞,有明显的K和Na中毒现象。After running for 22 080 h in the SCR denitrification system in one power plant, the used catalyst were characterized and its denitrification rate were investigated. The experimental results indicated that NOx removal rate of the power plant flue gas over the catalyst declined to 57% and the specific surface area decreased 2.48% - 5.12% after operation for 22 080 h. The results of XRD and XRF characteriza- tion showed that the catalyst was blocked by the dust and exhibited obvious poisoning phenomenon of K and Na.

关 键 词:催化剂工程 SCR脱硝催化剂 电厂烟气 性能 检测 

分 类 号:TQ426.94[化学工程] X701[环境科学与工程—环境工程]

 