某地表水源热泵项目水源条件分析  被引量:1

Analysis of Water Conditions for a Surface Water Source Heat Pump Project

在线阅读下载全文

作  者:郭彦玲[1] 康侍民[1] 林真国[1] 

机构地区:[1]重庆大学城市建设与环境工程学院,重庆400045

出  处:《制冷与空调(四川)》2012年第5期463-466,共4页Refrigeration and Air Conditioning

摘  要:水源条件对水源热泵工程的影响十分重要,直接决定水源热泵的系统的可行性。结合重庆某酒店水源热泵空调工程项目,分别从河水温度、流量、水质等方面对项目水源条件进行分析;简要介绍了项目河水水温和流量测试的测试仪器、方法;同时针对项目特点进行了水源热泵系统取退水方案设计。通过对项目水源条件的分析和取退水方案设计,表明本项目可采用直接式地表水水源热泵系统。Water conditions hold important implications for a water source heat pump project, which directly determine the feasibility of the water source heat pump system. Based on water source heat pump project in Chongqing, the water temperature, the flow-volume and the water quality were analyzed. The paper also briefly introduced the test instruments and methods for the river water temperature and flow-volume test. Then a scheme of the water supply and discharge system was designed according to characteristics of the project. The results show that the project can use direct type surface water source heat pump system.

关 键 词:地表水水源热泵 河水流量测试 取退水系统 

分 类 号:TK79[动力工程及工程热物理—流体机械及工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象