检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:姚俊[1] 段国军[2] 陈官国 彭海生 鲁富有 杨永军[2] 李华春[1]
机构地区:[1]云南省畜牧兽医科学院云南省热带亚热带动物病毒病重点实验室,云南昆明650224 [2]云南省丽江市华坪县畜牧兽医站,云南华坪674800 [3]云南省普洱市动物疫病预防控制中心,云南普洱665000
出 处:《山地农业生物学报》2012年第5期412-419,共8页Journal of Mountain Agriculture and Biology
基 金:云南省科技厅农业科技创新工程(2008LA019)
摘 要:根据GenBank中山羊痘病毒(AY077835)gp063基因DNA序列,应用Beacon Designer 7.0软件,设计合成1对引物和1条TaqMan探针,同时制备含有靶DNA序列的pEASY-T1重组质粒标准品。通过引物、探针浓度的筛选及反应条件的优化,建立了山羊痘病毒TaqMan法实时荧光定量PCR。该方法组内和组间重复试验变异系数均低于2%,最低浓度检测极限值为1×100copies/μL,上机检测时间少于40 min。运用该方法对不同时期流行于云南局部的山羊痘临床组织病料进行定量检测,生成的标准曲线斜率(Slope)为-3.36,截距(Intercept)为41.08,相关系数(R2)为0.999 989,阳性对照及送检样品抽提DNA中病毒含量依次为:P(TK)2.70×105copies/μL,华坪(HP)毒株1.45×106copies/μL,景谷(JG)毒株5.12×105copies/μL,保山(BS)毒株2.96×105copies/μL,宣威(XW)毒株1.86×105copies/μL,永胜(YS)毒株1.36×103copies/μL。结果表明:所建立方法具有灵敏、特异、安全、快速的特点,适合于山羊痘的早期检测。In order to develop a fluorescence quantitative detection method for goat pox virus ( GTPV), one pair of primers and a probe were designed for TaqMan real-time PCR based on gp063 gene sequence of goat pox virus genome( AY077835 ) available from NCBI GenBank. Meanwhile, pEASY - T1 recombinant plasmid that contains the target DNA sequence was prepared for quantitative detection of GTPV. With optimization of reaction conditions and concentration of primers and probe, a TaqMan real-time PCR assay for goat pox virus was developed. The coefficient of intra- and inter-variation of the assay were both less than 2% . The sensitiv- ity of the assay was 1×100 eopies/μL and the detection time was less than 40 rain. The developed assay was applied to quantitatively detect GTPV strains from clinical samples, which ever prevailed in some areas of Yunnan province in different periods. The slope, intercept and R2 of the standard curve was - 3.46, 41.08 and 0.999 989 respectively. The copies of GTPV virus in extracted DNA samples of TK (positive control), HP, JG, BS, XW and YS was 2.70×105 copies/μL, 1.45×106 copies/μL, 5. 12×105 copies/μL, 2.96×105 copies/μL, 1.86×105 copies/μL and 1.36×103 copies/μL respectively. The results showed that the TaqMan real-time fluorescence quantitative PCR assay is sensitive, specific, fast and safe, thus is suited for early detection of goat pox.
分 类 号:S855.3[农业科学—临床兽医学] Q789[农业科学—兽医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.221.54.244