纳米Ag/TiO_2涂层托槽的研制及力学性能  被引量:4

Development of a nanometer Ag/TiO_2 coated bracket and its mechanical properties

在线阅读下载全文

作  者:张晟[1] 麦理想[2] 柳大烈[3] 章锦才[1] 

机构地区:[1]广东省口腔医院.南方医科大学附属口腔医院正畸科,广东省广州市510280 [2]中山大学光华口腔医学院.附属口腔医院正畸科,广东省广州市510055 [3]南方医科大学珠江医院整形美容科,广东省广州市510200

出  处:《中国组织工程研究》2012年第38期7047-7052,共6页Chinese Journal of Tissue Engineering Research

基  金:广东省医学科学技术研究基金项目(B2011040)~~

摘  要:背景:前期实验发现纳米Ag可以原子态沉积于纳米TiO2涂层表面,增强涂层的可见光催化抗菌性能。目的:研制纳米Ag/TiO2涂层托槽,并分析其力学性能。方法:使用溶胶-凝胶法制备不同退火温度下的纳米Ag/TiO2涂层托槽,在扫描电镜下观察纳米Ag/TiO2涂层托槽的表面形貌;测量普通金属托槽、纳米TiO2涂层托槽和各组纳米Ag/TiO2涂层托槽的表面粗糙度;采用划痕实验法检测纳米TiO2涂层和各组纳米Ag/TiO2涂层与基体托槽的结合强度。结果与结论:纳米Ag/TiO2涂层厚度约120nm,为具有严整组织结构的纳米颗粒膜,表面平整、光滑、光洁度高,并可见Ag颗粒沉积在涂层上。纳米TiO2涂层托槽和各组纳米Ag/TiO2涂层托槽表面粗糙度与普通商业用托槽差别无差异(P>0.05);纳米TiO2涂层、120,200,300℃退火温度纳米Ag/TiO2涂层与基体托槽的结合强度分别为1.18,1.16,1.12,1.26kg。表明研制的纳米Ag/TiO2涂层托槽具有良好的力学性能,可以满足口腔正畸临床需要。BACKGROUND:In our prophase study,Ag can be deposited on TiO2 films,which can enhance the antibacterial effect of TiO2 coated films.OBJECTIVE:To develop a nanometer Ag/TiO2 coated bracket and to study its mechanical properties.METHODS:The nanometer Ag/TiO2 coated bracket was prepared using sol-gel method at different annealing temperatures.Scanning electron microscope was used to study the surface morphology of Ag/TiO2 coated bracket.The surface roughness of metal bracket,nanometer TiO2 coated bracket and nanometer Ag/TiO2 coated bracket was measured.The combination intensity of TiO2 and Ag/TiO2 coatings with brackets was measured by scratch test.RESULTS AND CONCLUSION:Nanometer Ag/TiO2 film was 120 nm in deepness,and it was a nanoparticle film with a thorough tissue structure.Ag particles were visibly deposited on the film surface that was flat,smooth,and highly polished.There were no significant differences among the surface roughness of nanometer TiO2 coated brackets,nanometer Ag/TiO2 coated brackets and brackets used commercially (P 0.05).The combination intensities of nanometer TiO2 and Ag/TiO2 coatings with brackets at annealing temperatures of 120,200 and 300 ℃ were 1.18,1.16,1.12 and 1.26 kg,respectively.These findings indicated that nanometer Ag/TiO2 coated bracket was developed successfully and it had good mechanical properties that could meet the clinical demand of orthodontics.

关 键 词:正畸托槽 纳米TIO2 纳米银 表面粗糙度 结合强度 生物材料 

分 类 号:R318[医药卫生—生物医学工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象