检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]华南理工大学电力学院,广东广州510640 [2]广州供电局有限公司,广东广州510310
出 处:《广东电力》2012年第10期51-55,共5页Guangdong Electric Power
摘 要:为了定量掌握运行环境对电缆导体温度的影响程度,以IEC60287电缆稳态温升公式为基础,推导出环境温度和环境热阻对导体温度影响的局部灵敏度公式。采用局部灵敏度分析法对影响电缆导体温度的2个环境因素进行分析,并进行了电缆温升试验。理论分析与试验结果表明,稳态运行下的电缆,导体温度直接受环境温度影响,环境温度越大则影响越明显,基本呈线性递增;环境热阻对导体温度的影响比较稳定,随着加载电流增大至另一个稳态,灵敏度系数只有小幅升高。For quantitatively mastering situation of impact degree of cable conductor temperature affected by operational en- vironment, this paper deduces a local sensitive formula for conductor temperature affected by environmental temperature and thermal resistance based on IEC 60287 steady state temperature rise formula. It analyzes two environmental factors which may influence cable conductor temperature by taking method of local sensitive analysis and carries out tests of cable temperature rise. Theoretical analysis and test results indicate that cable conductor temperature is directly affected by envi- ronmental temperature under the condition of steady state operation, while the environmental temperature is higher, the im- pact is more obvious which presents linear increasing trend. Meanwhile, the impact on conductor temperature by environ- mental thermal resistance is comparatively steady, while loading current increases to another steady state, the sensitive fac- tor only rises by small amplitude.
关 键 词:单芯电缆 IEC电缆稳态温升公式 环境温度 环境热阻 局部灵敏度分析法
分 类 号:TM247[一般工业技术—材料科学与工程]