ICP-MS同时测定饮用水中的19种元素  被引量:10

Simultaneous Determination of 19 Elements in Drinking Water by ICP-MS

在线阅读下载全文

作  者:唐文勇 许春凤 周智勇 李金国 胥川 罗婷 

机构地区:[1]四川绵阳水务(集团)有限公司水质检测中心

出  处:《光谱实验室》2012年第6期3508-3512,共5页Chinese Journal of Spectroscopy Laboratory

基  金:绵阳市科技计划项目(10S003)

摘  要:以Li、Sc、Ge、In、Bi作内标,采用电感耦合等离子体-质谱法(ICP-MS)同时测定饮用水中Fe、Hg、As、Pb等19种元素。方法的线性范围宽,灵敏度高,线性相关系数均不低于0.9990,相对标准偏差均在7.1%之内,各元素的加标回收率均92.5%—108.0%。方法准确、快速、便捷,能为绵阳灾后重建水质安全提供有力保障。19 elements in drinking water were detected simultaneously by inductively coupled plasma-mass spectrometer (ICP-MS) with Li, Sc, Ge, In and Bi as internal standards. The experimental results showed this method had a broad linear range and high sensitive with the linear correlation coefficients greater than 0. 9990,the relative standard deviations were less than 7.1% ,and the addition standard recoveries were in the range of 92. 5%-108.0%. The method is proved to be sensitive, rapid and accurate, and carl provide strong assurance for drinking water quality in reconstruction of Mianyang.

关 键 词:电感耦合等离子体-质谱法 饮用水 19种元素 