EMIA-320V型高频红外碳硫分析仪测定硅锰合金中硫的不确定度的评定  被引量:2

Uncertainty Evaluation of Determination of Sulfur in Silicomangan Alloy by EMIA-320V High Frequency Infrared Carbon-Sulfur Analyser

在线阅读下载全文

作  者:赵晶晶[1] 常健辉 

机构地区:[1]阿拉山口出入境检验检疫局技术中心 [2]中哈管道有限责任公司

出  处:《光谱实验室》2012年第6期3867-3871,共5页Chinese Journal of Spectroscopy Laboratory

摘  要:建立了高频红外碳硫分析仪测定硅锰合金中硫含量的相应数学模型,对数学模型中各个参数进行不确定度来源分析,分别对A类不确定度或B类不确定度进行评定。对各不确定度分量合成和扩展,得到硫质量分数的不确定度。结果表明,标准物质引入的不确定度是不确定度的主要来源。A corresponding mathematics model for the determination of sulfur in silicomangan by EMIA-320V high frequency carbon-sulfur analyser was established. The uncertainty source for each parameter in the mathematics model was analyzed. The uncertainties of type A or type B were evaluated. The components uncertainties were synthesized and extended, and the uncertainty of sulfur mass fraction was obtained. The results showed that the uncertainty of standard materials was the main source.

关 键 词:红外碳硫仪 硅锰合金  不确定度 

分 类 号:O657.33[理学—分析化学]

 