摘 要:核电站反应堆冷却剂系统的排放量的确定是硼回收系统设计运行能力的基本输入。压水堆核电厂硼回收系统的前贮槽、中间贮槽等重要设备容量均以该数值为基础进行设计。本文通过理论分析计算得出了压水堆核电厂硼回收系统的设计基准所需的循环冷却剂排放量,为该系统的工程设计提供了重要的设计依据和分析基础。The basic technical criteria of operation ability for the boron recycle system is the quantity of discharged reactor coolant for treatment,which is the basis of the capacity design of important equipments such as head storage tanks,intermediate storage tanks,etc.Through theoretical analysis and calculation,the paper gives out the discharge amount of recycled reactor coolant needed for pressurized water reactor power plant design basis.The discharge amount provides the critical design inputs and basis of analysis for engineering design of boron recycle system.