Epidural fentanyl decreases the minimum local analgesic concentration of epidural lidocaine  被引量:7

在线阅读下载全文

作  者:ZHANG Jian ZHENG Yue-ying FENG Zhi-ying CHEN Chao-qin ZHU Sheng-mei 

机构地区:[1]Department of Anesthesiology,First Affiliated Hospital,College of Medicine,Zhejiang University,Hangzhou,Zhejiang 310003,China

出  处:《Chinese Medical Journal》2012年第22期3977-3980,共4页中华医学杂志(英文版)

摘  要:Background Epidural lidocaine can be used when regional anesthesia needs to be established quickly, but the effect of co-administering epidural fentanyl on the minimum local analgesic concentration (MLAC) of lidocaine is not known. We compared the MLAC of epidural lidocaine in combination with different doses of fentanyl for epidural anesthesia in adults. Methods One hundred and twenty patients requiring epidural analgesia were randomly allocated to receive 20 ml of one of four solutions: lidocaine, or lidocaine plus fentanyl 1 pg/ml, 2 pg/ml, or 3 pg/ml. The first patient in each group was administered 1% lidocaine weight by volume; subsequent patients received a concentration determined by the response of the previous patient to a higher or lower concentration according to up and down sequential allocation in 0.1% increments. Efficacy was assessed using a visual analog pain scale, and accepted if this was 〈10 mm on a 100 mm scale within 30 minutes. The extent of motor block and of nausea and vomiting were recorded at 30 minutes after administration of the epidural solution and two hours after surgery, respectively. Results The MLAC of lidocaine in those receiving lidocaine alone was 0.785% (95%C/0.738-0.864). A significant dose-dependent reduction was observed with the addition of fentanyl: the MLAC of lidocaine with fentanyl at 2 pg/ml was 0.596% (95%C/0.537-0.660) and 0.387% with fentanyl at 3 pg/ml (95%C/0.329-0.446, P 〈0.001). Conclusion Epidural fentanyl significantly reduces the dose of lidocaine required for effective epidural analgesia in adults without causing adverse side effects. (Chi CTR-TRC-11001559)Background Epidural lidocaine can be used when regional anesthesia needs to be established quickly, but the effect of co-administering epidural fentanyl on the minimum local analgesic concentration (MLAC) of lidocaine is not known. We compared the MLAC of epidural lidocaine in combination with different doses of fentanyl for epidural anesthesia in adults. Methods One hundred and twenty patients requiring epidural analgesia were randomly allocated to receive 20 ml of one of four solutions: lidocaine, or lidocaine plus fentanyl 1 pg/ml, 2 pg/ml, or 3 pg/ml. The first patient in each group was administered 1% lidocaine weight by volume; subsequent patients received a concentration determined by the response of the previous patient to a higher or lower concentration according to up and down sequential allocation in 0.1% increments. Efficacy was assessed using a visual analog pain scale, and accepted if this was 〈10 mm on a 100 mm scale within 30 minutes. The extent of motor block and of nausea and vomiting were recorded at 30 minutes after administration of the epidural solution and two hours after surgery, respectively. Results The MLAC of lidocaine in those receiving lidocaine alone was 0.785% (95%C/0.738-0.864). A significant dose-dependent reduction was observed with the addition of fentanyl: the MLAC of lidocaine with fentanyl at 2 pg/ml was 0.596% (95%C/0.537-0.660) and 0.387% with fentanyl at 3 pg/ml (95%C/0.329-0.446, P 〈0.001). Conclusion Epidural fentanyl significantly reduces the dose of lidocaine required for effective epidural analgesia in adults without causing adverse side effects. (Chi CTR-TRC-11001559)

关 键 词:epidural anesthesia FENTANYL LIDOCAINE minimum local analgesic concentration 

分 类 号:Q14[生物学—生态学] TH777[生物学—普通生物学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象