检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]上海奉贤燃机发电有限公司,上海201403 [2]华东电力试验研究院有限公司,上海200437
出 处:《华电技术》2012年第A01期26-29,92,共4页HUADIAN TECHNOLOGY
摘 要:在控制联合循环机组余热锅炉化学水系统运行工况的过程中,存在着蒸汽氢电导率超标、汽包蒸汽带水和启动阶段水汽品质净化较慢等问题。从确保机组设备健康和安全角度出发,通过热化学试验和深入评估,建立安全、有效的化学水系统工况控制标准和灵活的监控体系。Some difficult problems exist in operation condition control of chemical water system of head recover boiler in gas-steam combined cycle unit,which include that the cation conductivity of the steam exceeds the standard,the steam in the steam drum contains water,it is more difficult to control the quality of water and steam during startup stage and so on.Starting from the target of ensuring the healthy and safety of the unit equipments,by the thermo-chemical test and the evaluation in depth,the safe and effective standard of operation condition control of the chemical water system and the flexible monitoring system were established.
关 键 词:余热锅炉 化学水系统 氢电导率 水汽品质 控制标准 监控体系 热化学试验
分 类 号:TK223.5[动力工程及工程热物理—动力机械及工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7