石化废水中水回用实验研究  被引量:1

Experimental study on the reclaimed water reuse of petrochemical wastewater

在线阅读下载全文

作  者:金宝丹 

机构地区:[1]北京京润新技术发展有限责任公司,北京100085

出  处:《工业水处理》2012年第11期65-68,共4页Industrial Water Treatment

摘  要:针对某石化企业污水处理厂出水水质,采用频繁倒极式电渗析设备对其进行深度处理,以达到循环水补水标准。中试实验结果显示:该工艺对所排放污水的总硬度、氯离子和电导率的去除率分别可达93.1%、93.8%和84.6%,出水总硬度、氯离子和电导率分别仅为27.4、28.4 mg/L和302.9μS/cm,完全符合循环水补水水质标准。经济分析显示:电渗析系统的运行成本仅为0.55元/m3,远小于自来水价格,说明污水回用有很好的经济优势。Aiming at the effluent water quality in the wastewater treatment plant of a petrochemical enterprise ,the frequent transform electrode electrodialysis equipment has been used for its advanced treatment, so as to reach the make-up water standard of circulating water. The pilot scale tests show that the removing rates of total hardness, chloride ion and conductivity can reach 93.1%, 93.8% and 84.6%, respectively. Using this process, the effluent total hardness is 27.4 mg/L,chloride ion is 28.4 mg/L,conductivity is 302.9 μS/cm,completely in accordance with the make-up water standard of circulating water. The economic analysis shows that the running cost of electrodialysis is only CNY 0.55/m3,which is much less than the price of tap water. It indicates that the wastewater reuse has pretty good economic advantages.

关 键 词:电渗析 中水回用 硬度 氯离子 电导率 

分 类 号:TE992.2[石油与天然气工程—石油机械设备]

 