检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:鲁先龙[1]
出 处:《电力建设》2012年第11期19-22,共4页Electric Power Construction
基 金:国家电网公司科技项目(GC17201100065)
摘 要:我国越来越多的输电线路工程需在杂填土地基中立塔,而杂填土地基杆塔基础选型、设计、地基处理方法及其工程设计参数,在相关设计技术规定和规范中均未给出具体规定。对杂填土地基输电线路杆塔基础工程技术进行探讨研究,给出了杂填土地基桩基础、筏型基础以及基于杂填土地基处理的杆塔基础方案及其适用条件,同时提出了通过试验确定杂填土地基工程性质的试验方法,相关成果可为设计提供参考。。More and more transmission line projects were built in miscellaneously backfilled soil areas. However, there were no special regulations on the selection and design of tower foundation, foundation treatment methods, and engineering design parameters for the miscellaneously backfilled soil. This paper investigated the engineering technology of tower foundation for transmission line in miscellaneously backfilled soil areas, and suggested the pile foundation, raft foundation, the tower foundation schemes and its applicable conditions. At last, the test methods for the determination of miscellaneously backfitled soil properties were proposed, which could provide references for the engineering design.
分 类 号:TM75[电气工程—电力系统及自动化]