高层建筑下部柱的选型与轴压比  被引量:1

Types and Maximum Axial Forces of Concrete Columns in the Lower of Tall Buildings

在线阅读下载全文

作  者:谭英韬[1] 陈满钢 王祖华[2] 

机构地区:[1]广州市城市规划勘测设计研究院,510060 [2]华南理工大学建工系,广州510641

出  处:《建筑结构》2000年第6期41-44,49,共5页Building Structure

摘  要:在高层和超高层钢筋混凝土建筑中,下部柱的内力很大,其轴力可以达到3000~4000kN甚至更高.在这种情况下,为减小柱子的截面,应视轴力的大小分别采用高强混凝土、约束混凝土、钢管混凝土和型钢混凝土或其复合柱.文中介绍了这些柱型的性能及在国内外的使用经验和轴压比限值,并给出了如何根据轴力大小进行选型的算例.In tall and ultra-tall concrete buildings, the internal axial force in the lower columns is possible to reach or exceeds 3 000-4 000kN. In this case,it is necessary to reduce the section of column by adopting the high strength concrete, restrained concrete, concrete filled steel tubes, steel reinforced concrete or composite and mixed construction. The behaviour, using experience at home and abroad and maximum axial force of a column section for these types of columns are introduced. A digital example about how to choose a column type according to the axial force is also given.

关 键 词:高层建筑 钢筋混凝土柱 钢管混凝土 组合结构 

分 类 号:TU973.14[建筑科学—结构工程] TU973.12

 