检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]华北电力大学电站设备状态监测与控制教育部重点实验室
出 处:《电站系统工程》2012年第6期38-40,共3页Power System Engineering
摘 要:设计气温的正确选择对空冷机组的安全经济的运行有着重要的意义。阐述了获取真实可靠气象资料的方法以及气温典型年的选择方法,总结了目前已有的确定设计气温的方法。对各个设计气温的选择方法进行了探讨分析,并应用于实例分析,得出各方法的可行性,并指出设计气温的确定可由+5℃以上全年加权平均气温法计算结果,充分考虑大气温度的逐年上升和热回流的产生,适当提高2~3℃后为设计气温。The reliable design temperature is important to the safe and economic operation of air cooling unit.The methods to obtain reliable meteorological data and air-temperature typical years are elaborated,summarized the existing methods that were used to determine the design temperature.All these methods were analyzed and used to solve actual problems,then the above +5℃ weighted average temperature method was use to determine the design temperature by analyzing every method's feasibility,the final design temperature was elevated 2~3℃ by considering the rising air temperature year after year and thermal reflux.
分 类 号:TM621.3[电气工程—电力系统及自动化]