检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]昆明医科大学第一附属医院影像科CT室,云南省昆明市650032
出 处:《中国组织工程研究》2012年第44期8298-8307,共10页Chinese Journal of Tissue Engineering Research
摘 要:背景:胸椎椎弓根螺钉置入前后CT扫描评价可以提高螺钉置入的准确性,并且避免螺钉置入时对周围神经血管损伤引起的严重并发症。目的:对胸椎椎弓根螺钉置入的CT评价应用进行深入分析,为提高改进椎弓根螺钉置入技术以及CT扫描在该领域的研究应用提供相关参考信息。方法:对SCI数据库2002至2011年收录的胸椎椎弓根螺钉置入的CT评价研究文献进行文献计量学分析和实验研究分析,分析文献的作者、机构以及国家地区明确世界范围对该领域的不同研究情况,分析胸椎椎弓根螺钉置入的CT评价的可行性、准确性、解剖结构风险以及疾病的临床应用,明确CT扫描对于胸椎椎弓根螺钉置入的应用范围。结果与结论:胸椎椎弓根螺钉置入的CT扫描评价具有较高的准确性,螺钉置入前CT扫描胸椎椎弓根及周围相邻结构评价椎弓根的形态以及与周围组织的结构关系,提高螺钉置入的准确性,避免神经血管损伤的并发症发生,螺钉置入后CT扫描胸椎椎弓根以及螺钉系统,评价螺钉置入的效果以及满意度,为制订后续的治疗方案提供帮助。BACKGROUND: CT evaluation and scanning before and after thoracic pedicle screw implantation can improve the accuracy of screw placement, and can avoid the serious complications caused by nerve and blood vessel injury during screw implantation. OBJECTIVE: To in-depth analyze CT evaluation and application for thoracic pedicle screw implantation, and to provide relevant reference information for improving pedicle screw implantation technology as well as the research and application of CT scans in the field. METHODS: The SCI database from 2002 to 2011 was searched for the articles on the CT evaluation for thoracic pedicle screw implantation, and the bibliometric analysis and experimental research and analysis were performed on these articles. We analyzed the author, institute and the countries of the articles in order to clear the research on this field worldwide. The feasibility, accuracy, risk of structure anatomy and the clinical application of CT evaluation for thoracic pedicle screw implantation were analyzed, and the application range of CT scanning for thoracic pedicle screw implantation was indentified. RESULTS AND CONCLUSION: The CT scan evaluation for thoracic pedicle screw implantation has a high accuracy. The CT scanning for the thoracic pedicle and adjacent structures around the screw placement before implantation can evaluate the morphology of the thoracic pedicle and the structural relationship with the surrounding tissue, improve the accuracy of screw implantation and avoid the complications caused by neurovascular injury. The CT scanning for the thoracic pedicle and screw system after implantation can evaluate the effect and satisfaction of screw implantation, in order to provide the assistance for developing follow-up treatment programs.
关 键 词:胸椎 椎弓根 螺钉 CT 并发症 颈动脉 椎动脉 食管 气管 脊柱侧凸 穿孔
分 类 号:R318[医药卫生—生物医学工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.229