检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]海军工程大学,湖北武汉430033
出 处:《舰船科学技术》2012年第11期59-63,共5页Ship Science and Technology
摘 要:针对MAX一体化压水堆建立反应堆主要系统及非能动余热排出系统的水力热工计算模型,以电源丧失事故为假想事故,利用该模型对事故过程进行仿真计算。分析结果表明,非能动余热排出系统配合一体化压水堆的高自然循环能力能够在发生电源丧失事故的情况下,明显减轻反应堆一、二回路压力边界的负担,降低堆芯温度,提高反应堆的安全性。The computing and analytic models are established for integrated pressurized water reactor (PWR) and passive residual heat removal system in one type of integrated nuclear power plant. Using the established mathematic models, the paper analyzes and calculates the transition process of blackout accident in two heat removal modes which are using safety valve and passive residual heat removal system. The calculation results show that, in blackout accident passive residual heat removal system cooperated with the natural circulation capacity of Integrated PWR can alleviate the burden of primary loop and secondary loop' s pressure boundary, reduce the temperature of in-core, improve the security of reactor.
分 类 号:TL421.1[核科学技术—核技术及应用]