检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
出 处:《工业安全与环保》2012年第11期80-83,共4页Industrial Safety and Environmental Protection
摘 要:以翻车卸料过程为研究对象,结合翻车工艺流程和翻车机室结构特点建立粉尘控制模型,采用吹吸气流从源头对开放性粉尘进行控制,给出了控制参数的计算方法,对控制结果进行了CFD模拟。模拟结果表明,吹吸气流能从源头对粉尘进行有效控制,工作区粉尘相对质量分数由78%降至9%,粉尘控制率为85%~90%。Taking the unloading process of ear dump as the research object, a dust control model is set up combined with the overturned process and the dumper chamber structure characteristics, in which the push- pull flow is adopted to control the openness dust from the source, the control parameters calculation method is given and the results of the model are simu- lated by CFD. Simulation results show that the push- pull flow can effectively control the dust from the source, the relative concentrations of dust the work area decreases from 78% to 9% and dust control rate from 85% to 90%.
分 类 号:X701.2[环境科学与工程—环境工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.74