检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
出 处:《华东电力》2012年第11期2012-2016,共5页East China Electric Power
摘 要:介绍了简化的配电网模型,对中性点经消弧线圈接地方式和经小电阻接地方式的运行特性进行了定量分析。研究了电容电流、中性点电阻和过渡电阻对过电压和故障电流的影响,通过仿真案例比较了两种接地方式的运行特点及优缺点。This paper presents the simplified distribution network model, and makes a quantitative analysis on the operation characteristics of the two neutral grounding modes : low resistance grounding and arc suppression coil grounding. Then the research focuses on the influence of capacitive current, neutral point resistance and transition resistance on over-voltage and fault current. Finally, the relevant cases have been simulated to compare the operation characteristics, as well as the pros and cons, of the two aforementioned neutral grounding modes.