自复位预制框架边节点抗震性能试验研究  被引量:45

Experimental study on behaviors of beam-column connections for self-centering post-tensioned precast frame

在线阅读下载全文

作  者:蔡小宁[1] 孟少平[2] 孙巍巍[3] 

机构地区:[1]淮海工学院,江苏连云港222005 [2]东南大学混凝土及预应力混凝土结构教育部重点实验室,江苏南京210096 [3]南京理工大学,江苏南京210094

出  处:《土木工程学报》2012年第12期29-37,共9页China Civil Engineering Journal

基  金:江苏省自然科学基金(BK2011707)

摘  要:提出一种新型的自复位预应力预制节点形式PTED节点,为了研究PTED节点的抗震性能,进行5个PTED边节点的低周往复荷载试验,对试件的滞回曲线、骨架曲线、刚度退化、耗能能力、延性及残余变形等抗震性能进行分析,试验结果表明:加载到层间位移角为4%时,预应力筋保持在弹性阶段,梁柱连接处缝隙及梁自身的裂缝均能在预应力筋的回弹作用下闭合,节点残余变形较小,PTED节点具有良好的自复位的能力,提高了震后结构的可修复性。加载过程中,梁柱基本保持弹性,而通过角钢的弹塑性变形耗散能量。增大角钢厚度、长度,增大梁高及减小预应力筋的初始应力可提高节点的耗能能力。节点的承载力随梁高的增加、预应力筋初始应力的增大、角钢厚度和长度的增大而提高。在加载后期,节点承受的荷载仍持续增长,加载到4%时,PTED节点仍具有稳定的屈服后刚度。PTED节点还具有较好的延性和梁端转动能力。PTED节点具有良好的抗震性能,可在地震区推广应用。A kind of new self-centering post-tensioned precast connections ( simplified as PTED) is proposed. In order to ~tudy the seismic behaviors of the PTED connections, the low cyclic loading tests of the PTED connections were carried out. The hysteresis curves, skeleton curves, stiffness degradation curves, energy dissipation coefficients and residual deformations of the PTED connections were analyzed. The test results shows that when the story drift reaches 4%, the tendons remains elastic, the gap at the beam-column connections and the beam cracks could be closed under the resilience of the tendons. The residual deformations of the PTED connections are small, which indicate that the connections have good self-centering ability and can improve the repairable capability of the structures after the earthquake. The beams and columns remained elastic, and the connections dissipated the energy by the elastic-plastic deformations of the angles. The angle thickness and length increase, the beam height increase and the stress of the tendons decrease can all improve the energy dissipation capacity of the PTED connections. The load-bearing capacity of the connections increase with the beam height, the initial stress of the tendons and the thickness and length of the angles. When the story drift reaches 4%, the PTED connections still keep a stable post-yield stiffness. The analysis shows that due to their good ductility, rotation capacity and good seismic behaviors, the PTED connections can be applied in the seismic zones.

关 键 词:自复位 预制 角钢 预应力 抗震性能 

分 类 号:TU378.8[建筑科学—结构工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象