ICP-MS法测定兰索拉唑中钒残留  被引量:2

Determination of trace amounts of vanadium in medicines of lansoprazole by ICP-MS

在线阅读下载全文

作  者:张兰[1] 龙智翔[1] 谢涛[1] 黎德南 

机构地区:[1]广西壮族自治区分析测试研究中心,南宁530022 [2]桂林华信制药有限公司,桂林541200

出  处:《现代仪器》2012年第6期77-78,76,共3页Modern Instruments

基  金:广西壮族自治区直属公益性科研院所基本科研业务费专项项目(项目编号:2011ACZ08)

摘  要:建立ICP-MS测定痕量钒的测定方法。通过试验优选适宜的仪器测定参数,并进行方法试验。方法线性范围1-100μg/L,检出限0.305μg/L,加标回收率101%-110%。结果表明,在选定的仪器工作条件下测定,精密度和准确度均满足要求。The determination of trace vanadium was performed by inductively coupled plasma-mass spectrometry(ICP-MS).The digestion condition and the parameters of ICP-MS were optimized.The linear range of lansoprazole was 1-100μg/L,detection limit of the method was 0.305μg/L and the recoveries were between 101%-110%.The results show that the method has good accuracy and precision and it can meet the requirements of analysis under the optimum conditions.

关 键 词:ICP-MS  兰索拉唑 