电感耦合等离子体原子发射光谱法同时测定锌电解液中铜镉钴  被引量:5

Simultaneous determination of copper,cadmium and cobalt in zinc electrolyte by inductively coupled plasma atomic emission spectrometry

在线阅读下载全文

作  者:陈希[1] 郭方遒[1] 黄兰芳[1] 张洁[1] 阳春华[2] 

机构地区:[1]中南大学化学化工学院,湖南长沙410083 [2]中南大学信息科学与工程学院,湖南长沙410083

出  处:《冶金分析》2012年第11期51-55,共5页Metallurgical Analysis

基  金:国家自然科学基金(60874069)

摘  要:研究了用电感耦合等离子体原子发射光谱法(ICP-AES)直接同时测定锌电解液中的铜、镉、钴含量的方法。试样不经预处理,在3%(V/V)的HNO3介质中,以327.393nm、226.502nm、228.616nm波长的谱线分别作为铜、镉、钴的分析线,通过选择分析线和调扣背景点来消除或减少背景干扰和重叠干扰,采用基体匹配方法克服基体效应,用ICP-AES测定了冶炼厂锌电解液中的铜、镉、钴含量。该法操作简单,分析快速、可靠,样品的测定值与极谱法的测定值相符,相对标准偏差在0.7%~1.3%之间,可用于锌电解液中杂质元素含量的控制分析。The direct and simultaneous determination of copper, cadmium and cobalt in zinc electrolyte by inductively coupled plasma atomic emission spectrometry (ICP-AES) was studied. Sample did not need pretreatment. The spectral lines with wavelengths of 327. 393 nm, 226. 502 nm and 228. 616nm were selected as the analytical lines of copper, cadmium and cobalt respectively. The background in- terference and overlap interference were eliminated or reduced by selecting analysis line and adjusting background points. The effect of the matrix was overcome by matrix matching method. The contents of copper, cadmium and cobalt in smelter zinc electrolyte were determined by ICP-AES in 3 % (V/V) HNO3 medium. The method was simple, rapid and reliable. The measured value of sample was con- sistent with the results of polarography, with the relative standard deviation of 0.7%- 1. 3%. The method can be used for the control analysis of the contents of impurity elements in zinc electrolyte.

关 键 词:锌电解液    电感耦合等离子体原子发射光谱法(ICP-AES) 基体匹配 

分 类 号:O657.31[理学—分析化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象