机构地区:[1]张家口供电公司,河北张家口075000 [2]冀北电力有限公司,北京100053
出 处:《电力电容器与无功补偿》2012年第6期69-76,共8页Power Capacitor & Reactive Power Compensation
摘 要:结合串补保护与控制系统运维经验的研究,对现有串补系统中保护与控制系统的配置、二次系统抗干扰、硬件系统和软件系统及逻辑等方面存在的问题进行了详细分析,并提出针对性、实用化的防范措施。该研究成果有利于现有串补保护与控制系统运行、维护和管理,并能在系统的改造和优化工程中起到积极的指导作用,同时也是串补保护与控制系统国产化研究进程中的重要参考。In this paper, problems in such fields as configuration of protection and control system of existed series compensation system, anti-interference of secondary system, hardware and software systems and operation logic are analyzed in detail with combination of study of operation and mainte- nance experience of series compensation protection and control system. The pertinence and practical precaution measures are proposed. The research result is helpful to operation, maintenance and man- agement of existed series compensation protection and control system, plays an actively instructive role in the modification and optimization of the system, and is of important reference in the localiza- tion research of series compensation protection and control system.
分 类 号:TM77[电气工程—电力系统及自动化]