检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张锡德[1] 董泰斌[1] 刘昌伟[1] 李莉[1]
机构地区:[1]中国石油塔里木油田公司石化分公司,新疆库尔勒841000
出 处:《大氮肥》2012年第6期424-426,共3页Large Scale Nitrogenous Fertilizer Industry
摘 要:介绍合成气压缩机汽轮机转速下降、转速无法控制的事故现象及特点,根据事故特征对控制系统测试,确认该事故是由汽轮机V2阀控制系统中电液转换器内一线圈短路造成。找出线圈短路的根源,更换电液转换器信号线,对V1阀和V2阀控制系统进行调试,提出对汽轮机重新进行保温,对信号线加强监护等防范措施。The trouble and feature in revolution drop and revolution-not-control of steam turbine for syngas compressor is introduced and a test is made on the control system based on the trouble features and it is confirmed that the trouble is caused by short-circuit of a coil inside the electro-liquid converter for control system of steam turbine. When the source of coil short-circuits is found a signal-line for electro-liquid con- verter is replaced and control system tunning of V1 and V2 valves implemented;it is suggested that measures such as a re-insulation to steam turbine and intensive care of signal-line are carried out.
分 类 号:TQ545[化学工程—煤化学工程]
正在载入数据...