氢电导率和脱气氢电导率联合测试技术在凝结水系统故障识别中的应用  被引量:8

Application of Joint Testing Technology of Cation Conductivity and Degassed Cation Conductivity in Failure Identification for Water Condenser System

在线阅读下载全文

作  者:王国蓉 李继刚 游喆[3] 王安宁[3] 祝青[3] 费剑影[3] 施依娜[3] 

机构地区:[1]望亭发电厂,江苏苏州215155 [2]上海漕泾热电有限责任公司,上海201424 [3]华东电力试验研究院有限公司,上海200437

出  处:《净水技术》2012年第6期77-81,共5页Water Purification Technology

摘  要:针对大机组存在的凝汽器真空度不佳和微量渗漏现象无法有效甄别的问题,提出了氢电导率和脱气氢电导率联合测试技术加以解决。采用凝结水氢电导率和脱气氢电导率联合测试技术,实现对氯离子和二氧化碳含量的监控,可有效识别凝结水系统故障,其原理在于凝结水中二氧化碳含量过高的主要诱因为真空严密性不良,而不挥发性杂质含量升高则与凝汽器泄漏有关。Considering difficult differentiating between bad vacuum and light leak of condenser, combined test technology of cation conductivity and degassed cation conductivity was put forward to resolve. Combined test of cation conductivity and degassed cation conductivity for condensate can inspect the content of chloride and carbon dioxide, which can distinguish the failure of condenser system. The principle consists of higher carbon dioxide content related to bad vacuum and higher fixed impurity content related to leak of the condenser.

关 键 词:氢电导率 脱气氢电导率 凝汽器 凝结水 

分 类 号:TM621.8[电气工程—电力系统及自动化]

 