检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:黄惠琴[1] 张志喜[1] 蒋春林[1] 刘长河[1]
机构地区:[1]中国冶金地质总局西北局酒泉中心实验室,甘肃酒泉735009
出 处:《分析测试技术与仪器》2012年第4期222-226,共5页Analysis and Testing Technology and Instruments
摘 要:样品经王水分解后,在电感耦合等离子体发射光谱仪上测定了样品溶液中磷的含量.通过实验确定了基体元素的干扰、酸度、样品提升量、雾化气流速、功率、观测高度、分析谱线等分析条件.通过铁的干扰实验结果表明,样品中的基体元素铁不影响磷含量的测定.在用P178.222 nm分析线测定时,方法的检出限为P 0.0006%(相对于0.1 g样品,定容至100 mL),相对标准偏差在3.14%~6.04%(n=11),样品加标回收率在92%~110%.方法测定样品中磷含量的结果同光度法测定结果对比数据相符.After the sample is decomposed with aqua regia, the determination of phosphorus content in the sample solution by inductively coupled plasma atomic emission spectrometry is carried out. Through experiments the analysis conditions such as the matrix interference, acidity, enhance ment of amount of samples, gas velocity of atomization, power, height of observation, analytical spectral lines are determined. The results show that the interference of iron, sample matrix of elemental iron does not affect the determination of phosphonis content. In the P 178. 222 nm line determination, the detection limit was P 0. 0006% ( corresponding to 0.1 g of sample, in a constant volume of 100 mL) , the relative standard deviation was 3.14% - 6.04% ( n = 11 ) , the rates of spiked recovery were 92% - 110%. The results of the determination of phosphorus content in the sample by this method accorded with the results of photometric determination.
关 键 词:王水分解 电感耦合等离子体发射光谱法 铁矿石 磷