铁碳微电解法预处理CLT酸废水的试验研究  被引量:2

Experimental study on pretreatment of CLT acid wastewater by iron-carbon micro-electrolysis

在线阅读下载全文

作  者:陆兆华[1] 朱大明[1] 陈凯华 潘建通 

机构地区:[1]中国矿业大学(北京),北京100083 [2]北京博汇特环保科技有限公司,北京100102

出  处:《工业用水与废水》2012年第6期40-43,共4页Industrial Water & Wastewater

摘  要:采用铁碳微电解法对CLT酸废水进行预处理,分别研究了气水体积比、pH值、铁碳体积比、HRT及H2O2投加量对处理效果的影响。试验结果表明:气水体积比为3、pH值为2.0、HRT为100 min、铁碳体积比为1.25时的处理效果最好,CODCr的去除率达到40%以上。加入适量的H2O2能进一步提高CODCr去除效率,在H2O2(35%)的投加量为10 mL/L时,CODCr的去除率达到60%左右,m(BOD5)/m(CODCr)值达到0.2,为CLT酸废水的预处理提供科学依据。Iron-carbon micro-electrolysis process was used to pretreat CLT acid wastewater. The influences of air-water volume ratio, pH value, volume ratio of iron to carbon, HRT and H202 dosage on treatment effect were investigated. The results of the test showed that: when the air-water volume ratio was 3 : 1, the pH value was 2.0, the HRT was 100 min, and the volume ratio of iron to carbon was 1.25, the best treatment effect could be obtained, and the removal rate of CODa reached above 40%. It could be seen that, adding proper amount of H202 could improve the removal rate of CODcr, when the dosage of H2O2 (35%) was 10 mL/L, the removal rate of CODcr was about 60%, the value of m(BOD5)/m(CODcr) was 0.2, which provided scientific basis for CLT acid

关 键 词:CLT酸废水 铁碳微电解 气水体积比 H2O2 

分 类 号:X703.1[环境科学与工程—环境工程]

 