弹塑性缓冲限位与滞变-摩擦并联隔震体系参数分析  被引量:7

Analysis on parameters of hysteretic-friction isolated system with elastic-plastic displacement-constraint device

在线阅读下载全文

作  者:赵桂峰[1] 马玉宏[2] 张永山[1] 

机构地区:[1]广州大学土木工程学院,广东广州510006 [2]广州大学减震控制与结构安全重点实验室,广东广州510405

出  处:《建筑结构学报》2013年第1期131-138,共8页Journal of Building Structures

基  金:国家自然科学基金重大研究计划重点项目(90815027);“十二五”国家科技支撑计划(2012BAJ07B02);广东省科技计划项目(2009B020311006)

摘  要:针对弹塑性缓冲限位与滞变-摩擦并联隔震体系,建立了隔震系统的恢复力模型和隔震体系的运动方程;根据缓冲限位装置的作用机理,定义了隔震层与缓冲限位装置软碰撞和脱离接触过程中的软碰撞拐点和恢复力拐点,给出了拐点时刻的缓冲限位装置位移和恢复力的计算公式,编制了相应隔震体系的非线性分析程序,分析了缓冲限位装置的缓冲限位距离、弹性刚度、屈服位移等关键参数对隔震体系的影响。研究表明:弹塑性缓冲限位距离的合理取值范围为60~100 mm;缓冲限位装置与滞变-摩擦隔震装置的设计参数完全相同,但缓冲限位装置的设置数量为滞变-摩擦隔震装置数量的一半;与仅滞变-摩擦隔震情况相比,并联隔震体系隔震层位移控制效果在30%以上;与无控情况相比,并联隔震体系的上部结构层间位移控制效果在40%以上。In this research,for the hysteretic-friction system with elastic-plastic displacement-constraint device,the total restoring force model was developed.The motion equation of the isolated system was established.According to the action mechanism of elastic-plastic displacement-constraint device,soft-collision inflection point and restored-force inflection point during the course of colliding and disconnecting between the isolation layer and the displacement-constraint device,were defined.The computational formula of inflection time was given.And the nonlinear analysis program of the corresponding isolated system was worked out.Then,the influence factors such as displacement-constraint distance,elastic stiffness and yield displacement of the displacement-constraint device on the base isolation system were analyzed in detail.The results show that rational distance of the displacement-constraint device is 60-100 mm.The design parameter of the displacement-constraint device is the same as the hysteretic-friction isolation device,but the number is half.Compared with the pure hysteretic-friction isolated system,the isolation effect for the displacement of isolated layer basically is greater than 30%.At the same time,compared with the non-isolated building,the isolation effect of storey-displacement for upper structure is greater than 40%.

关 键 词:隔震体系 缓冲限位 滞变-摩擦 非线性分析 隔震效果 

分 类 号:TU352.12[建筑科学—结构工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象