电感耦合等离子体原子发射光谱法测定铁硅铝中的铈  被引量:2

Determination of cerium in iron-silicon-aluminum alloy with ICP-AES

在线阅读下载全文

作  者:陈美娜[1] 罗仕莲[1] 黄中越[1] 程石[1] 李彩华[1] 

机构地区:[1]广东省冶金产品质量监督检测中心,广东广州510640

出  处:《南方金属》2012年第6期22-23,53,共3页Southern Metals

摘  要:研究电感耦合等离子体原子发射光谱(ICP-AES)法直接测定铁硅铝合金中的铈,选择最佳分析线,确定适宜的基体浓度,并研究了基体对铈测定的影响,得到铈的检出限为0.020μg/mL.用此方法对样品进行分析,得到分析结果的相对标准偏差RSD均小于2!(n=6),加标回收率为96!~106!.该方法简便、快速,准确,能够满足生产需要.A study was made of determining cerium in iron-silicon-aluminum alloy using inductance-coupled ICP-AES in the paper. The operation condition of the instrument was optimized, the composition of the alloy matrix determined, and its effect on the cerium determination studied, which yielded a detection limit for the cerium below 0. 020 μg/mL, a relative standard deviations RSD less than 2%( n = 6), and a recovery rate tested by standard addition method ranging from 96%to 106%. Being simple, rapid and precise, the method has been successfully applied to production practice.

关 键 词: 铁硅铝合金 原子发射光谱 电感耦合 

分 类 号:TG115.33[金属学及工艺—物理冶金]

 