检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:杨东伟[1] 郁鸿凌[1] 管晨希[1] 肖博钧[1]
机构地区:[1]上海理工大学能源与动力工程学院,上海200093
出 处:《上海理工大学学报》2012年第6期589-592,共4页Journal of University of Shanghai For Science and Technology
摘 要:针对冷凝脱湿的特性,利用能效分析法、物料平衡法和热力平衡法建立了高炉鼓风系统冷能利用的分析模型.对某钢厂的高炉鼓风冷却脱湿系统的实际数据进行整理归纳并利用该模型进行计算分析,结果表明:该钢厂高炉鼓风脱湿系统的冷能利用不充分.为提高冷能利用,盛夏月份每日产生的22.56T/h、10℃冷凝水量,经处理可以回收利用到单台冷冻机的冷凝器,降低冷凝器侧循环冷却水温度1℃,增强了冷凝器换热效果和制冷系统制冷量352kW,提高了高炉鼓风脱湿系统的冷能效用.According to the characters of condensing dehumidification, the energy efficiency method,material balance method and heat balance method were used to build-an analytical model about the cascade use of cooling energy in blast furnace (BF) blower system. The actual data, which were collected from a steel-works, were settled and then analyzed by means of the analytical model. The results show that the cooling energy in the steel-works' BF blower dehumidifying system is not fully used. For better use,the condensed water,with a production rate of 22.56 tons an hour at 10 ℃in July and August, can be used in the condenser of one refrigerator after water treatment, and lower the cooling water temperature by 1 ℃ Meanwhile, it can enhance heat transferring and increase the cooling energy of refrigerating system by 352 kW.
分 类 号:TK011[动力工程及工程热物理]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.3