储罐区防火堤高度探讨  被引量:7

Discussion on the fire dike safetyof the tank farm

在线阅读下载全文

作  者:伍军学 任常兴[2] 李晋[2] 

机构地区:[1]天津中滨海盛科技发展有限公司,天津300384 [2]公安部天津消防研究所,天津300381

出  处:《消防科学与技术》2013年第1期28-30,共3页Fire Science and Technology

基  金:国家"十二五"科技支撑计划项目(2011BAK03B08-02)

摘  要:结合国内外现行相关规范标准,探讨了储罐区防火堤有效容积和高度的安全要求,并进行了防火堤内储罐抗浮力分析。以10×104 m3大型浮顶油罐区"4罐一组"和"6罐一组"典型布置方式为例,计算评估了防火堤浸液储罐的浮起高度,为提高大型油罐区防火堤的安全性和经济合理性提供参考。According to the present code and standards at home and abroad, the effective volume and height of fire dike in tank farm was discussed, and the tank buoyancy in its fire dike was calculated and analyzed. As an illustrative example of a representative group of four or six storage tanks, the float height of a large floating-roof tank farm with some release crude into fire dike was evaluated. This study is beneficial to improving the fire dike more safe and economical in the large tank farm.

关 键 词:储罐区 防火堤高度 浮力计算 

分 类 号:X913.4[环境科学与工程—安全科学] TU249.9[建筑科学—建筑设计及理论]

 