检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:潘超[1,2] 王泽忠[1] 杨敬瑀[1] 刘连光[1]
机构地区:[1]华北电力大学电气与电子工程学院,北京102206 [2]东北电力大学电气工程学院,吉林132012
出 处:《电工技术学报》2012年第12期226-232,239,共8页Transactions of China Electrotechnical Society
基 金:国家国际科技合作项目(2010DFA64680);北京市优秀博士学位论文指导教师科技项目(YB20101007901)
摘 要:变压器瞬态场路耦合计算存在稳定性、计算效率及精确度的问题。利用瞬态场路耦合方法,结合能量扰动原理计算磁场变化对应的动态电感。根据四阶龙格库塔法求解的高阶收敛性,推导绝对稳定域以判断计算是否收敛,分析时间步长与状态矩阵特征值的关系,定义电感变化函数评价磁场计算精确度。对单相变压器建模和仿真,计算正常运行和直流偏磁时的瞬态磁场和等效电路参数,研究耦合参数在不同励磁饱和程度时的变化规律,结果说明利用动态电感参数可以反映时变的励磁饱和情况。与传统欧拉法和改进欧拉法对比,四阶龙格库塔法具有更高的稳定性和精确性,同时验证了绝对稳定域的正确性。以稳定性为前提,合理选取磁场求解频率可以有效提高计算效率和精确度。通过实验验证了瞬态场路耦合计算的可行性和稳定性分析的可靠性,为实际变压器瞬态场路计算提供新的思路。Problems about stability,efficiency and accuracy in the computation of transformer,which are based on the transient magnetic-electric coupled method,have been concerned.Dynamic inductance is calculated according to the energy perturbation.Combining with the high-order convergence of the fourth Runge-Kutta,the absolutely stable region is determined to judge the convergence of computation.And the variation function of dynamic inductances is established to evaluate the magnetic changing.Then an actual single-phase transformer is modeled and simulated.Computation and case study about normal operation and DC-biasing are given to work out the transient magnetic and equivalent circuit parameters.The varying regularity of coupling parameters in different saturated excitations is learned,and the relation between state matrix and time step is studied.Result shows that the dynamic inductances are feasible to reflect the time-varying magnetic saturation.Compared with the traditional and improved Euler method,the fourth Runge-Kutta takes advantages in stability and accuracy.Meanwhile,the absolutely stable region is valid.On the basis of stability analysis,proper solving frequency of magnetic field can optimize the computational accuracy and efficiency.Tests are carried out to prove the transient magnetic-circuit method and stability analysis,which will be a new way for practical DC-biased transformers.
分 类 号:TM74[电气工程—电力系统及自动化] TM41
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.119.143.52