两种CAD软件对体模肺结节CT体积测量的比较研究  被引量:2

Comparative study of two kinds of CAD softwares for volumetric measurement of lung nodules——a phantom study

在线阅读下载全文

作  者:李敏[1] 龚建平[2] 张伟[2] 钱铭辉[2] 

机构地区:[1]苏州大学附属传染病医院放射科,江苏215007 [2]苏州大学附属第二医院影像科,江苏215000

出  处:《放射学实践》2013年第1期17-20,共4页Radiologic Practice

摘  要:目的:评估肺部CT智能诊断报告系统软件和Lung VCAR软件在测量体模结节体积方面的准确性和一致性。方法:使用植入直径为2.5、5.0、10.0和20.0mm的孤立结节的商用体模,采用64层螺旋CT机进行体模扫描。结节标准体积采用公式V=4/3πr3计算。分别使用肺部CT智能诊断报告系统软件和Lung VCAR软件对体模扫描数据进行分析,测量体模结节的体积。结果:两种软件对肺结节体模中16个结节均能进行相应的分析和体积测量。肺部CT智能诊断报告系统软件测量直径2.5、5.0、10.0和20.0mm结节体积的平均相对误差分别为21.1%、-4.7%、-1.6%和-2.3%;Lung VCAR软件的平均相对误差分别为15.5%、3.1%、2.7%和1.4%。通过Bland-Altman分析,显示两种软件对体模结节体积测量的相对误差具有较好的一致性。结论:肺部CT智能诊断报告系统软件虽然比Lung VCAR软件在体模结节体积测量上准确性稍低,但两者对于体模结节体积测量具有较好的一致性。Objective:To evaluate the accuracy and the consistency of CT phantom nodule volumetry measurement with pulmonary CT intellective CAD software and Lung VCAR sotware. Methods: Spherical nodules 2. 5ram, 5. 0mm, 10.0mm and 20.0ram in diameter were placed within a commercially available lung phantom and scanned by a 64-slice CT scanner. Nodule volume (V) was measured by the formula V--(4/3)nr3. Automated nodule volume measurements were performed by using the two above-mentioned CAD softwares independently. Results:The volume of all 16 nodules within the phantom could be measured and analyzed by the two softwares. The average relative errors of nodules 2. 5mm, 5. 0mm, 10.0ram and 20ram in diameter were 21.1%,-4.7%,-1.6% and --2.3% respectively with pulmonary CT intellective CAD software. The average relative errors of nodules 2. 5ram, 5. 0mm, 10.0ram and 20.0ram in diameter were 15. 5%, 3.1 % ,2.7 % and 1.4 % respectively with Lung VCAR software. There was no substantial difference in the volume estima- tions between the two CAD softwares by Bland Altman analysis. Conclusion: Although the accuracy of volumetry measure- ment with pulmonary CT intellective CAD software was lower than that of lung VCAR, but still there was high consistency between the two CAD softwares.

关 键 词:体模 结节 体积测量 体层摄影术 X线计算机 

分 类 号:R816.4[医药卫生—放射医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象