纳氏试剂分光光度法测定环境空气中氨的不确定度评定  被引量:3

The Uncertainty Evaluation of Ammonia Determination in Ambient air by Nessler's Reagent Spetcrophotometry

在线阅读下载全文

作  者:胡俊庆[1] 陈国美 王晓玉[1] 

机构地区:[1]大庆市环境监测中心站,黑龙江大庆163316 [2]大庆市萨尔图区环境监测站,黑龙江大庆163311

出  处:《干旱环境监测》2012年第4期233-238,共6页Arid Environmental Monitoring

摘  要:对《环境空气和废气氨的测定纳氏试剂分光光度法》(HJ 533-2009)测试氨过程中不确定度的影响因素进行了分析,其主要来源为标准溶液、标准曲线拟合、样品重复测定、分光光度计、取吸收液体积和采集气样气体标况体积这六部分引入的不确定度。本次测量合成不确定度为0.042,最大的相对不确定度分量为大气采样器流量计引入(0.029)。本次环境空气中氨测定结果为0.142±0.012 mg/m3,k=2(约95%置信水平)。Uncertainty in the ambient air and exhaust gas ammonia Nessler' s reagent spectrophotometry (HJ 533 - 2009) test ammonia process influencing factors are analyzed, the main source am the standard solution, standard curve fitting, repeat samples determination, spectrophotometer, absorb the hquid volume and the collection of gas samples from gas standard volumetric. The measurement combined uncertainty is 0.042, the largest relative uncertainty components is the introduction of air sampler flowmeter (0.029) .The determination results of ammonia in ambient air is 0.142 ± 0.012 mg/m^3 , k = 2 (95% confidence level).

关 键 词:不确定度 评定 环境空气  测定 

分 类 号:X830.5[环境科学与工程—环境工程]

 