检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:林斌飞[1] 龙伟[1] 万汉伟[1] 邓雅婷[1]
出 处:《传感器与微系统》2013年第1期102-104,111,共4页Transducer and Microsystem Technologies
基 金:2011年江西省研究生创新专项资金资助项目(YC2011-S002)
摘 要:介绍了一种高精度分光光度计系统的设计方法及其临床应用。该系统充分利用全息凹面光栅色散器件的优势,结合复杂可编程逻辑器件(CPLD)可自由编程的步进电机细分电路设计和电机定位闭环控制技术,实现了320~800 nm连续光谱范围内1 nm的高精度分光。由该系统作为核心传感部件的生化分析仪临床应用表明:系统具有连续光谱分布范围广、分光精度高、运行稳定和检测可靠等优点。Design method and clinical application of a high precision spectrophotometer system is introduced.The system fully uses advantage of dispersive device which based on holographic concave grating,combined with freely programmable CPLD stepper motor sub-circuit technology and closed-loop motor positioning control technology to realize the high precision spectral of 1 nm in the range of 320 -800 nm continuous spectrum.Clinical application of biochemical analyzer which based on the system as the core sensing component shows that the system has advantages,such as continuous spectrum distribution scope,high spectral precision,stable operation,reliable detection and so on.