检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]重庆大学动力工程学院,重庆400030 [2]重庆大学低品位能源利用技术及系统教育部重点实验室,重庆400030
出 处:《低温与超导》2013年第1期41-44,54,共5页Cryogenics and Superconductivity
基 金:国家重点基础研究发展计划项目(2011CB710701);重庆大学"211工程"三期建设(S-09101)资助
摘 要:提出了分级再生式转轮除湿和蒸发冷却相结合的空调系统,依据除湿和再生过程的质量守恒和能量守恒方程,结合边界条件和初始条件建立除湿转轮和空调系统的数学模型,对比分析了分级再生空调系统的性能。研究结果表明:采用分级再生的转轮可达到与一般再生转轮相同的除湿效果。与一般再生的空调系统相比,分级再生式空调系统的再生能耗降低了约50%,热力性能系数提高了约90%。A desiccant and evaporative cooling system with staged - regeneration was proposed. According to the mass and energy conservation equation in the dehumidification and the regeneration process combined with the boundary and initial conditions, the mathematical model of the desiccant wheel and air conditioning system was established. The results showed that the desiccant wheel with staged regeneration could achieve the same dehumidifying effect. Compared with the air conditioning system with general regeneration, the energy consumption for regeneration of the system with staged - regeneration could decrease about 50%, and the thermodynamic coefficient of performance could increase about 90%.
分 类 号:TU831.3[建筑科学—供热、供燃气、通风及空调工程]