连续流动分析法测定烟草中K^+和Cl~–的不确定度评定  被引量:2

Evaluation of Uncertainty of the Determination of Potassium and Chloride Ions in Tobacco by the Continuous Flow Method

在线阅读下载全文

作  者:武士杰[1] 潘纯祥 夏启东 杨蕾 王保兴[3] 

机构地区:[1]云南师范大学,昆明650092 [2]云南瑞升烟草技术(集团)有限公司,昆明650106 [3]云南烟草科学研究院,昆明650106

出  处:《化学分析计量》2013年第1期82-85,88,共5页Chemical Analysis And Meterage

摘  要:采用连续流动分析法测定烟草中钾离子和氯离子含量,分析了测量不确定度的主要来源如样品水分测量、萃取液体积、样品浓度等,对各不确定度度分量进行了评定和计算。当钾离子、氯离子含量分别为1.66%,0.61%时,扩展不确定度分别为0.04%,0.02%。提出了连续流动分析法测定烟草中钾离子和氯离子时保证结果准确可靠的措施。Potassium and chloride ion content in the tobacco were determined by continuous flow analysis method. Resources of determination uncertanity such as water detection, extraction solution volume, sample concentration and so on were analysed. Uncertainty component was evaluated and calculated. The expanded uncertainty was 0.04% for potassium and 0.02% for chloride as potassium and chloride content were 1.66% and 0.61%, respectively. Measures were proposed to guarantee the accuracy of the results detected by continuous flow analysis method.

关 键 词:连续流动分析法 烟草 K+ Cl– 不确定度评定 

分 类 号:O657.9[理学—分析化学]

 