丁二酮肟光度法测定不锈钢中高镍含量的不确定度评定  被引量:1

Uncertainty Evaluation of Determination of High Content Nickel in Stainless Steel by Dimethylglyoxime Spectrophotometry

在线阅读下载全文

作  者:刘文异 张爱武 王洪敏 

机构地区:[1]东北工业集团有限公司吉林江机公司计量测试中心,吉林省吉林市132021

出  处:《化学分析计量》2013年第1期86-88,共3页Chemical Analysis And Meterage

摘  要:采用丁二酮肟光度法测定不锈钢中高含量镍,分析了影响测定结果准确度的各种因素,测定结果不确定度的来源主要包括测量重复性、试样溶液中镍浓度、试样溶液体积、称样量等7个方面,对各个不确定度分量进行了评定和计算,当不锈钢中镍的含量为35.633%时,扩展不确定度为0.254%(k=2)。High content nickel in stainless steel was determined by dimethylglyoxime spectrophotometry and factors influenced accuracy of detection results were ananlysed. Main sources of determination uncertainty were measurement such as repeatability, nickel concentration, sample solution volume, sample weight etc. Each component of uncertainty was evaluated and calculated. Expanded uncertainty was 0.254%(k=2) as nickel content was 35.633%.

关 键 词:丁二酮肟光度法  不锈钢 不确定度 

分 类 号:O657.32[理学—分析化学]

 