拭样增菌对实时荧光PCR法检测孕妇B族链球菌感染的影响  被引量:14

Effect of Swabs Enrichment on the Detection of Group B-Streptococcal Infection in Gravid Women by Real-time Fluorescent PCR

在线阅读下载全文

作  者:边佳明[1] 丁媛媛[1] 杨凡[1] 张梅[1] 许景峰[1] 

机构地区:[1]北京军区总医院药理科临床基因扩增检验室,北京100700

出  处:《现代检验医学杂志》2012年第6期102-104,共3页Journal of Modern Laboratory Medicine

摘  要:目的比较拭样增茵或不增茵对实时荧光PCR法检测孕妇产道B族链球菌感染率的影响。方法收集临床孕35~37周妇女阴道直肠拭子1000例,平均分为增茵检测组和未增茵检测组。增茵组拭子置于增菌液室温过夜增菌后40C保存待检,未增茵组拭子直接4℃保存待检,所有PCR检测在临床采样后48h内完成,检验指标为B族链球菌的阳性检出率。结果X2检验结果显示,拭样增茵显著影响实时荧光PCR法对B族链球菌的阳性检出率,增菌后B族链球茵阳性检出率提高了1.7倍(P=0.006)。结论提取前对临床标本适当增茵在临床PCR检验实验室具有可操作性,更好地避免了假阴性的出现,提升了B族链球菌产前筛查的意义。Objective To compare the effect of swabs enrichment on the detection of group B-streptococcal (GBS) infection by real-time fluorescent PCR in birth canal of gravid women. Methods 1 000 vagina-rectum swabs at 35~37 week's gesta- tion were collected and evenly divided into enrichment group and non-enrichment group. Swabs of enrichment group were en- riched in sterile broth overnight at room temperature followed by storage at 4~3 ready for detection,while swabs of non-en- richment group were stored at 4℃ ready for detection. All PCR detections must be completed within 48h to statistic GBS i- solating rate. Results Chisquare test showed that enrichment before DNA extraction remarkably affected isolating rate of GBS by real-time fluorescent PCR,and enrichment group had a higher isolating rate (1.7 times of control,P=0. 006) than non-enrichment group. Conclusion The proper enrichment for clinical specimens is very feasible in clinical gene amplifica- tion test lab,by which false-negative was greatlyavoided,improving the value of GES screen before delivery

关 键 词:实时荧光PCR B族链球菌 围产期 

分 类 号:R378.12[医药卫生—病原生物学] Q503[医药卫生—基础医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象