卡培他滨中有机残留溶剂的检测  被引量:4

Determination of residual organic solvents in capecitabine

在线阅读下载全文

作  者:益磊 单静静 周志美[1] 耿武松 孟祥松[1] 蒋磊[1] 

机构地区:[1]亳州市食品药品检验所,安徽亳州236800 [2]安徽恒星制药有限公司,合肥230000

出  处:《中南药学》2013年第1期60-62,共3页Central South Pharmacy

摘  要:目的建立气相色谱法测定卡培他滨原料药中二氯甲烷、乙醇、甲醇和乙酸乙酯4种有机溶剂。方法采用DB-624毛细管柱,FID检测器,以DMSO为溶剂。结果各有机溶剂的平均加样回收率为93.7%~97.6%,RSD为2.5%~3.7%。结论该方法稳定准确,可用于卡培他滨中有机溶剂残留的检测。Objective To establish a GC method for the determination of residual organic volatitl solvents-dichloromethane,methanol,ethyl acetate and sthanolin tiotropium bromide in capecitabine.Methods A DB-624 capillary column was used,with FID as the detector and DMSO as the solvent.Results The average recoveries were 93.7%-97.6%,with RSDs of 2.5%-3.7%.Conclusion The method is stable and accurate,and can apply to the determination of the 4 residual organic solvents in capecitabine.

关 键 词:卡培他滨 有机溶剂残留 气相色谱 检测 

分 类 号:R917[医药卫生—药物分析学] R927[医药卫生—药学]

 