检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:吴转琴[1] 尚仁杰[1] 洪光[1] 夏京亮[1] 寅志强[1]
出 处:《建筑结构》2013年第2期68-70,共3页Building Structure
摘 要:缓粘结预应力钢绞线与混凝土之间的粘结锚固性能关系到缓粘结预应力混凝土结构的受力,通过对8个试件的拉拔试验,研究了缓粘结预应力钢绞线与混凝土之间的粘结锚固性能,测得了钢绞线拉力与滑移量之间的关系曲线。试验证明,缓粘结钢绞线外包护套的横肋高度直接影响到缓粘结钢绞线与混凝土之间的粘结性能,横肋越高,钢绞线从混凝土试件中拔出的拉拔力越大,粘结性能越好。试验结果对缓粘结钢绞线的制作和缓粘结预应力混凝土结构设计和工程应用提供参考。The cohesive anchorage property between retard-bonded prestressing steel strand and concrete is important to the retard-bonded prestressed concrete structure.The pull-out experiments of 8 test specimens were carried out to study the cohesive anchorage property of retard-bonded prestressing steel strand,and the curves of load versus slide displacement were obtained.It is shown that the cohesive anchorage property is affected by the height of the transverse rib directly.The higher the transverse rib is,the larger the pull-out force would be.The study provides a reference for the fabrication of the retard-bonded prestressing steel strand and the design of the retard-bonded prestressed concrete structure.