“立体定向三点一线择优穿刺法”在甲状腺结节微创组织病理活检术中的应用价值  被引量:6

The value of "stereotactic three-point-one-line optimal puncture "in thyroid nodule minimally invasive biopsy surgery

在线阅读下载全文

作  者:张大奇[1] 周乐[1] 付言涛[1] 付庆峰[1] 丛丹[1] 张广[1] 边学海[1] 赵涛[1] 孙辉[1] 

机构地区:[1]吉林大学中日联谊医院甲状腺外科,吉林长春130033

出  处:《中国实验诊断学》2013年第2期284-286,共3页Chinese Journal of Laboratory Diagnosis

摘  要:目的探讨"立体定向三点一线择优穿刺法"在超声引导甲状腺结节微创组织病理活检术中的应用价值。方法总结分析2009年9月—2012年4月我科应用"立体定向三点一线择优穿刺法"完成甲状腺结节微创组织病理活检921例(共1030个结节)的临床资料。结果 921例穿刺术用时6~26分钟,平均13分钟。结节直径0.3~2.3cm,平均0.92cm。结节直径<0.5cm 165例,占17.9%。结节紧邻颈部大血管、神经、气管及食道("危险区")135例,占14.6%。921例患者活检取材,穿刺成功率为100%(921/921)。活检诊断为甲状腺癌的269例,良性病变652例。活检后行手术治疗385例,病理符合率98.4%。假阴性(甲状腺癌误诊为良性疾病)6例,假阴性率1.6%(6/385)。无假阳性。活检后患者均未出现明显不适,发生腺体表面及肌间少许渗出34例,无明显血肿形成,未经特殊处置,平均1个月后自行吸收。结论 "立体定向三点一线择优穿刺法"应用简便、准确,缩短了手术时间,同时提高了病理的检出率,降低了手术风险。提高了手术的成功率。Objective To investigate the value of “stereotactic three-point-one-line optimal puncture”in ultrasound- guided thyroid nodule minimally invasive biopsy surgery. Methods Take clinical data of 921 cases(1030 nodules) from September 2009 to April 2002 applying“stereotactic three-point-one-line optimal puncture ” minimally invasive biopsy into analysis. Results Operation time were 6 ~26 minutes in all cases,with an average of 13 minutes. Nodule diameter ranged in 0.3 ~ 2.3 cm,with an average of 0.92 cm. In 165 cases,nodule diameter were lower than 0.5cm,aecounting for 17.9 %. In 1 35 cases, nodules tightly close to cervical vessels, nerves, trachea and esophagus (as the “danger zone”) accounting for 14.6 %. All of 921 patients accepted puncture biopsy with success rate of 100 % (921/921). Biopsy diag- nosed 269 cases of thyroid carcinoma,652 cases of benign lesions. 385 cases underwent surgical treatment after biopsy, and pathological, coincidence rate reached to 98.4 %. Six cases confirmed false negatives (thyroid cancer misdiagnosed as benign disease) ,with false-negative rate of 1.60/00 (6/385). No false positive cases. Afte biopsies patients showed no ob vious discomfort,no obvious hematoma formation,although 34 cases occurred little effusion on the gland surface or in- termuscle without special treatment,and finally selbabsorbed within an average of one month. Conclusion “Stereotactic three-point-on-line optimal puncture” is simple, accurate, shortening the operation time. Additionally, the method im prove the pathological detection rate and success rate of surgery,and reduce the risk of surgery.

关 键 词:立体定向 三点一线择优穿刺法 甲状腺结节 活检 

分 类 号:R581.3[医药卫生—内分泌]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象